Heat, specific heat & calorimetry
Heat (q) flows from hot to cold until everything reaches one temperature.
Heat (q) flows from hot to cold until everything reaches one temperature. The amount of heat a sample absorbs depends on its mass, its specific heat capacity and its temperature change: q = m·c·ΔT. Calorimetry is just bookkeeping: heat lost by one thing = heat gained by another.
Signs: system vs surroundings
- Endothermic (ΔH > 0): the system absorbs heat, so the surroundings (water, solution) get colder. Dissolving NH₄NO₃ is the classic example.
- Exothermic (ΔH < 0): the system releases heat and the surroundings get warmer — combustion, neutralization, precipitation.
- “How much energy is required to heat…” → q is positive for the sample, so heating is endothermic for the sample.
Coffee-cup method
- Mass of solution = mass of water + mass of solute, or total volume × density (1.00 g/mL when told).
- q_solution = m c ΔT, using the solution’s c (4.18 or 4.2 J/g°C — use what they give).
- q_rxn = −q_solution. Temperature dropped? q_rxn is positive (endothermic).
- Divide by moles (of the limiting reactant) and convert J → kJ.
Heating curves (phase changes)
On a heating curve, temperature stays flat during a phase change — the energy goes into breaking intermolecular forces. Each sloped segment is m·c·ΔT with that phase’s c; each flat segment is n·ΔH_fus or n·ΔH_vap.
Ethanol boils at 78.4 °C, so there are three steps: warm the liquid, boil it, warm the gas. (c_liquid 2.46, c_gas 1.33 J/g°C, ΔH_vap 42.3 kJ/mol.)
① 40.0 g × 2.46 J/g°C × (78.4 − 20.0) = 5747 J = 5.747 kJ
② (40.0 / 46.07) mol × 42.3 kJ/mol = 36.73 kJ
③ 40.0 g × 1.33 J/g°C × (90.0 − 78.4) = 617.1 J = 0.617 kJ
Total = 43.1 kJ. Notice the vaporization step is ~85% of the heat — and the J vs kJ trap.
30.0 g tea (4.15 J/g°C, 60.0 °C) + 20.0 g milk (3.85 J/g°C, 5.0 °C).
T_f = (30.0·4.15·60.0 + 20.0·3.85·5.0) ÷ (30.0·4.15 + 20.0·3.85) = (7470 + 385) ÷ 201.5 = 39.0 °C — closer to the tea’s temperature because it has the larger heat capacity (m × c).
Calorimetry solver (4 modes)
Heating-curve calculator
- Mixing J and kJ when adding heating-curve steps.
- Forgetting the negative sign: q_rxn = −q_solution.
- Using only the water’s mass when the problem says to use the solution (water + solute or combined volumes).
- Bomb calorimeters use C_cal (kJ/°C) — no mass, no c.